Skip to main content
Plaque métallique carrée, couleur grise, surface lisse et uniforme.
  • Bureau

Dalle KA2

La KA2 tray floor panel is specially designed for raised access floors in commercial buildings subject to height constraints and enhanced fire safety requirements.Thanks to its thin calcium sulphate core combined with a double galvanised steel facing, it combines an M0 classification, good acoustic ... See more
Icône d'une vanne à clapet dans un cercle gris, indiquant un composant mécanique.
Available in low thickness
Icône de sécurité indiquant un produit ignifuge, avec un symbole de flamme barrée.
Fire-resistant panels

Product benefits

Fire safety designed for limited voids.

La KA2 tray floor panel is specially designed for raised access floors in commercial buildings subject to height constraints and enhanced fire safety requirements.

Thanks to its thin calcium sulphate core combined with a double galvanised steel facing, it combines an M0 classification, good acoustic performance and excellent mechanical strength while preserving a useful underfloor plenum.

Intended for offices, high-rise buildings (IGH) and buildings open to the public, it provides a reliable, adaptable solution particularly suited to renovation projects or configurations with limited void depth.

  • M0 classification : meets the fire safety requirements for ERP, IGH and sensitive buildings.
  • Thin profile : ideal for renovation projects and low installation depths.
  • Compatible with insurance requirements : facilitates consideration of fire safety constraints and contributes to risk control.
  • Acoustic comfort : calcium sulphate core providing superior insulation to Traditional floor panels.
  • Modular and scalable : permanent access to the underfloor plenum to accommodate changes to building services.
  • Value-enhancing : adds value to Commercial projects in both construction and renovation.

Technical characteristics

Dimensions (mm)600 x 600 mm
Safety coefficient2
Thickness panel (mm)25 mm
Weight (Kg)13,7 kg

Performances

Reaction to fire

M0

Acoustic (dB): lateral insulation (with/without carpet)

50/45 (depending on thickness, composition and coating of the floor panels)

Acoustic (dB): shock noise (with/without carpet)

52/45 (depending on thickness, composition and coating of the floor panels)

Transverse electric resistance

109 to 1012 Ω (depending on the properties of the coating and the design of the floor panel)

Technical focus

Composition floor panel KA2

  • 25 mm calcium sulphate core
  • Lower tray in galvanised steel
  • Upper galvanised steel metal sheet
  • Without coating for loose-lay carpet
Section de bord de panneau en matériau composite gris et blanc.

50 Years of Expertisein Industrial Manufacturing

Made in Francewith Complete System Expertise

Critical Infrastructureand demanding projects